Incubator/Radiant Warmer Analyzer

Protect a baby’s safety by regularly performing all necessary preventive maintenance tests on infant incubators and radiant warmers. Life matters. Testing matters.
The equipment is an all-in-one Incubator/Radiant Warmer Analyzer that simplifies testing and ensures proper performance and safety of infant incubators, transport incubators and radiant warmers by complying to global standards (IEC60601-2-19, IEC 60601-2-20, IEC 60601-2-21).
Portable and intuitive-to-use, the equipment simultaneously tests temperature, airflow, sound, and humidity. Test results and parameters can be monitored in real-time on a large easy-to-read LCD screen, or be transferred to your computer wirelessly*.
Pass/Fail indicators are displayed at the end of tests for fast and easy troubleshooting, and a general testing option allows you to complete a quick test in just 15 minutes.
The equipment can stay in the incubator chamber up to 24 hours using its rechargeable battery, or for 48 hours on AC power, without compromising the integrity of the test environment.

Description

HIGHLIGHTS

Enables simultaneous measurement of humidity, airflow, sound, and temperature from six different points

Displays pass/fail indicators and real-time test results on a large LCD screen

Wireless* functionality supports fast and convenient downloading of test results and data

Able to choose from 10 different language interfaces

Portable and compact design, weighs less than three pounds

Has both Standards-based testing and a General Testing option which allows you to complete a test in as little as 15 minutes

Creates personalized test sequences for automatic test completion

Simplifies test set-up with color-coded temperature probes that match color of input ports

Complies with all global standards, including IEC 60601-2-19, IEC 60601-2-20 and IEC 60601-2-21

Measurements and tests specifications

Air convection peripheral temperature sensors for incubator (T1-T5)5 sensors
Range: 0 °C to 50 °C
Accuracy: ±0.05 °C
Display resolution: 0.01 °C
Air convection temperature sensors for radiant warmers, sensors in pucks (black discs)5 pucks
Range: 0 °C to 50 °C
Accuracy: ± 0.2 °C
Display resolution: 0.01 °C
Relative humidityRange: 0 % to 100 %,
Accuracy: +/- 3 % RH (0 % to 100 % non-condensing)
Display resolution: 0.1 % RH
AirflowRange: 0.2 m/sec to 2.0 m/sec at 35°C, 50 % RH
Accuracy: +0.1 m/sec
Display Resolution: 0.01 m/sec
Sound pressure30 dB(A) to 100 dB(A)
Accuracy: ± 5 dB(A)
Display resolution: 0.1 dB(A)
IEC-61672-1 Class 2 from 31.5Hz to 8kHz
Surface temperature-5 °C to 60 °C
Accuracy: ± 0.5 °C
Display resolution: 0.05 °C
Skin temperature probe with reference thermometer0 °C to 50 °C
Accuracy: ±0.05 °C
Display resolution: 0.01 °C

Environmental specifications

Operating temperature10 °C to 40 °C
Storage temperature-20 °C to 60 °C
Humidity10 % to 90 % non-condensing
Altitude2000 m
Ingress protection ratingIP-20
Safety
IEC 61010-1Overvoltage category none, pollution degree 2
IEC 61326-1Basic

Electromagnetic compatibility (EMC)


Emissions classification IEC CISPR11: Group 1, Class A.Group 1 has intentionally generated and/or use conductively coupled radio-frequency energy, which is necessary for the internal functioning of the equipment itself. Class A equipment is suitable for use in nondomestic locations and/or directly connected to a low voltage power supply network.
USA (FCC) Intentional radiatorsThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. (15.19)
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
Wireless module listing
FCC (United States) compliant (Class A)FCC ID: X3ZBTMOD3
IC (Industry Canada) compliantIC: 8828A-MOD3
CE (European) certifiedCE0051
802.15.1 qualifiedQD ID: B019224
Wireless radio
Frequency range2412 MHz to 2483 MHz
Output power10 mW
Interface
Push navigation buttonsPower on/off, test, select, back, and arrow keys
User PreferencesAdjust backlight, display brightness, and set clock
Recall and run templates on testerGeneral and personalized test templates allow for on-board test automation
TemplatesTime duration, frequency of data capture and tests
Select user preferencesUnits of measure, view test results of current and past tests on the Analyzer
View battery lifeIndicator bar shows life remaining
Interface languagesEnglish, French, German, Italian, Spanish, Brazilian Portuguese, Simplified Chinese, Japanese, Russian, Polish
Size (HxWxL without sensors)23 cm x 21 cm x 6 cm (9.0 in x 8.5 in x 2.5 in)
Total weight3.9 kg (8.5 lb)
Weight with sensors1.4 kg (3 lb)
Pucks (5)2.5 kg (5.5 lb)
Carrying case1.1 kg (2.5 lb)
Power Adapter – Universal voltageInput: 100 V to 240 V with adaptors 50 Hz/60 Hz
Output: 15V dc, 1.3 A maximum
Rechargeable lithium-ion battery, internal7.4 V, 7.8 Ah, 58 Wh 24 hour battery life with 30 second sample rate

The Fluke Biomedical INCU II is an all-in-one Incubator/Radiant Warmer Analyzer that simplifies testing and ensures proper performance and safety of infant incubators, transport incubators and radiant warmers by complying to global standards (IEC60601-2-19, IEC 60601-2-20, IEC 60601-2-21).
Portable and intuitive-to-use, the INCU II simultaneously tests temperature, airflow, sound, and humidity.

4720996 INCU II-Cable K-Type Thermocouple
4721000 INCU II S Sensor Sound Sensor
4721017 INCU II A F Sensor Air Flow Sensor
4721021 INCU II H Sensor Humidity Sensor
4721039 INCU II R Sensor Red Temperature Sensor
4721042 INCU II G Sensor Green Temperature Sensor
4721056 INCU II Y Sensor Yellow Temperature Sensor
4721063 INCU II W Sensor White Temperature Sensor
4721074 INCU II B Sensor Blue Temperature Sensor
4721109 INCU II Spacers Tripod Spacers
4721111 INCU II R Puck Red Temperature Puck
4721127 INCU II G Puck Green Temperature Puck
4721130 INCU II Y Puck Yellow Temperature Puck
4721148 INCU II W Puck White Temperature Puck
4721153 INCU II B Puck Blue Temperature Puck
4721166 INCU II USB Type A to Micro B, USB Cable
4721194 INCU II Adapter AC Adapter
4715713 INCU II Pad Placement Pad Microfi ber
4715749 INCU II Carry Case Soft Carry Case
4724692 INCU II Puck Case Soft Carry Case Puck

4721175 INCU II ST Heater Skin Temperature Heater Assembly

Updating…

Ansur 3.1.4 Executive Software
Updating…

Additional information

Origin

USA

Type

Manual

You've just added this product to the cart: