Inverter 3-8kW Energy Fronius
- Description
- Additional information
Description
HIGHLIGHTS
Updating..
TYPE | PRIMO 3.8-1 | PRIMO 5.0-1 |
Input (DC) | ||
Max. permitted PV power | 5.7 kW | 7.5 kW |
Max. usable input current (MPPT 1/MPPT 2) | 18 A / 18 A | 18 A / 18 A |
Total max. DC current | 36 A | 36 A |
Max. admissible input current (MPPT 1/MPPT 2) | 27 A | 27 A |
Operating voltage range | 80 V – 1,000 V | 80 V – 1,000 V |
Max. input voltage | 1,000 V | 1,000 V |
Nominal input voltage | 410 V | 420 V |
Admissible conductor size DC | AWG 14 – AWG 6 | AWG 14 – AWG 6 |
MPP voltage range | 200 – 800 V | 240 – 800 V |
Number of MPPT | 2 | 2 |
OUTPUT DATA | ||
Max. output power 240 V | 3,800 W | 5,000 W |
208 | 3,800 W | 5,000 W |
Max. output fault current / Duration 240 V | 584 A Peak / 154 ms | 584 A Peak / 154 ms |
Max. continuous output current 240 V | 15.8 A | 20.8 A |
208 V | 18.3 A | 24.0 A |
Recommended OCPD/AC breaker size 240 V | 20 A | 30 A |
208 V | 25 A | 30 A |
Max. efficiency (Lite version) | 97.90% | 97.90% |
CEC efficiency (Lite version) 240 V | 95.50% | 96.50% |
Admissible conductor size AC | AWG 14 – AWG 6 | AWG 14 – AWG 6 |
Grid connection | 208 / 240 V | 208 / 240 V |
Frequency | 60 Hz | 60 Hz |
Total harmonic distortion | < 5.0 % | < 5.0 % |
Power factor (cos φac,r) | 0.85 – 1 ind./cap | 0.85 – 1 ind./cap |
GENERAL DATA | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS |
Dimensions (width x height x depth) | 16.9 x 24.7 x 8.1 in. / 42.9 x 62.7 x 20.6 cm | 16.9 x 24.7 x 8.1 in. / 42.9 x 62.7 x 20.6 cm |
Weight | 47.4 lb. / 21.5 kg | 47.4 lb. / 21.5 kg |
Degree of protection | NEMA 4X | NEMA 4X |
Night time consumption | < 1 W | < 1 W |
Inverter topology | Transformerless | Transformerless |
Cooling | Controlled forced ventilation, variable speed fan | Controlled forced ventilation, variable speed fan |
Installation | Indoor and outdoor installation | Indoor and outdoor installation |
Ambient operating temperature range | -40 to 131 F / -40 to 55 C | -40 to 131 F / -40 to 55 C |
Permitted humidity | 0 – 100 % | 0 – 100 % |
DC connection terminals | 2x DC+1, 2x DC+2 and 4x DC- screw terminals for solid: copper and aluminium stranded / fine stranded: copper and aluminium | 2x DC+1, 2x DC+2 and 4x DC- screw terminals for solid: copper and aluminium stranded / fine stranded: copper and aluminium |
AC connection terminals | Screw terminals 12 – 6 AWG | Screw terminals 12 – 6 AWG |
Revenue Grade Metering | Optional (ANSI C12.1 accuracy) | Optional (ANSI C12.1 accuracy) |
ertificates and compliance with standards | UL 1741-2015, UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC 2014 Article 690, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 | UL 1741-2010, UL1998 (for functions: AFCI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2008, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 ( September 2001), UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 |
PROTECTIVE DEVICES | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS |
AFCI & 2014 NEC Compliant | Yes | Yes |
DC disconnect | Yes | Yes |
DC reverse polarity protection | Yes | Yes |
Ground Fault Protection with Isolation Monitor Interrupter | Yes | Yes |
INTERFACES /AVAILABILITY | AVAILABLE WITH ALL FRONIUS SYMO MODELS | AVAILABLE WITH ALL FRONIUS SYMO MODELS |
USB (A socket) Standard | Datalogging and inverter update via USB | Datalogging and inverter update via USB |
2 x RS422 (RJ45 socket) Standard | Fronius Solar Net, interface protocol | Fronius Solar Net, interface protocol |
Wi-Fi/Ethernet/Serial/ Datalogger and webserver Optional | Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU | Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU |
6 inputs and 4 digital I/Os Optional | Load management; signaling, multipurpose I/O | Load management; signaling, multipurpose I/O |
TYPE | PRIMO 6.0-1 | PRIMO 7.6-1 | PRIMO 8.2-1 |
Input (DC) | |||
Max. permitted PV power | 9.0 kW | 11.4 kW | 12.3 kW |
Max. usable input current (MPPT 1/MPPT 2) | 18 A / 18 A | 18 A / 18 A | 18 A / 18 A |
Total max. DC current | 36 A | 36 A | 36 A |
Max. admissible input current (MPPT 1/MPPT 2) | 27 A | 27 A | 27 A |
Operating voltage range | 80 V – 1,000 V | 80 V – 1,000 V | 80 V – 1,000 V |
Max. input voltage | 1,000 V | 1,000 V | 1,000 V |
Nominal input voltage | 420 V | 420 V | 420 V |
Admissible conductor size DC | AWG 14 – AWG 6 | AWG 14 – AWG 6 | AWG 14 – AWG 6 |
MPP voltage range | 240 – 800 V | 250 – 800 V | 270 – 800 V |
Number of MPPT | 2 | 2 | 2 |
OUTPUT DATA | |||
Max. output power 240 V | 6,000 W | 7,600 W | 8,200 W |
208 | 6,000 W | 7,600 W | 7,900 W |
Max. output fault current / Duration 240 V | 584 A Peak / 154 ms | 584 A Peak / 154 ms | 584 A Peak / 154 ms |
Max. continuous output current 240 V | 25.0 A | 31.7 A | 34.2 A |
208 V | 28.8 A | 36.5 A | 38.0 A |
Recommended OCPD/AC breaker size 240 V | 35 A | 40 A | 45 A |
208 V | 40 A | 50 A | 50 A |
Max. efficiency (Lite version) | 97.90% | 97.90% | 97.90% |
CEC efficiency (Lite version) 240 V | 96.50% | 97.00% | 97.00% |
Admissible conductor size AC | AWG 14 – AWG 6 | AWG 14 – AWG 6 | AWG 14 – AWG 6 |
Grid connection | 208 / 240 V | 208 / 240 V | 208 / 240 V |
Frequency | 60 Hz | 60 Hz | 60 Hz |
Total harmonic distortion | < 5.0 % | < 5.0 % | < 5.0 % |
Power factor (cos φac,r) | 0.85 – 1 ind./cap | 0.85 – 1 ind./cap | 0.85 – 1 ind./cap |
GENERAL DATA | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS |
Dimensions (width x height x depth) | 16.9 x 24.7 x 8.1 in. / 42.9 x 62.7 x 20.6 cm | 20.1 x 28.5 x 8.9 in. / 51.1 x 72.4 x 20.6 cm | 20.1 x 28.5 x 8.9 in. / 51.1 x 72.4 x 20.6 cm |
Weight | 47.4 lb. / 21.5 kg | 82.5 lbs. / 37.4 kg | 82.5 lbs. / 37.4 kg |
Degree of protection | NEMA 4X | NEMA 4X | NEMA 4X |
Night time consumption | < 1 W | < 1 W | < 1 W |
Inverter topology | Transformerless | Transformerless | Transformerless |
Cooling | Controlled forced ventilation, variable speed fan | Controlled forced ventilation, variable speed fan | Controlled forced ventilation, variable speed fan |
Installation | Indoor and outdoor installation | Indoor and outdoor installation | Indoor and outdoor installation |
Ambient operating temperature range | -40 F to 140 F (-40 to 60 C) | -40 to 140 F / -40 to 60 C | -40 to 140 F / -40 to 60 C |
Permitted humidity | 0 – 100 % (non-condensing) | 0 – 100 % | 0 – 100 % |
DC connection terminals | 6 x DC+ and 6 x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminum (solid / stranded) | 4x DC+1, 2x DC+2 and 6x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminum (solid / stranded) | 4x DC+1, 2x DC+2 and 6x DC- screw terminals for copper (solid / stranded / fine stranded) or aluminum (solid / stranded) |
AC connection terminals | Screw terminals 14-6 AWG | Screw terminals 12 – 6 AWG | Screw terminals 12 – 6 AWG |
Revenue Grade Metering | Optional (ANSI C12.1 accuracy) | Optional (ANSI C12.1 accuracy) | |
ertificates and compliance with standards | UL 1741-2010, UL1998 (for functions: AFCI and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2008, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690, C22. 2 No. 107.1-01 ( September 2001), UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 | UL 1741-2015, UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690-2014, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 | UL 1741-2015, UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC Article 690-2014, C22. 2 No. 107.1-01 (September 2001) , UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 -2013 |
PROTECTIVE DEVICES | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS | STANDARD WITH ALL FRONIUS SYMO MODELS |
AFCI & 2014 NEC Compliant | Yes | Yes | Yes |
DC disconnect | Yes | Yes | Yes |
DC reverse polarity protection | Yes | Yes | Yes |
Ground Fault Protection with Isolation Monitor Interrupter | Yes | Yes | Yes |
INTERFACES /AVAILABILITY | AVAILABLE WITH ALL FRONIUS SYMO MODELS | AVAILABLE WITH ALL FRONIUS SYMO MODELS | AVAILABLE WITH ALL FRONIUS SYMO MODELS |
USB (A socket) Standard | Datalogging and inverter update via USB | Datalogging and inverter update via USB | Datalogging and inverter update via USB |
2 x RS422 (RJ45 socket) Standard | Fronius Solar Net, interface protocol | Fronius Solar Net, interface protocol | Fronius Solar Net, interface protocol |
Wi-Fi/Ethernet/Serial/ Datalogger and webserver Optional | Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU | Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU | Wireless standard 802.11 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modbus RTU |
6 inputs and 4 digital I/Os Optional | Load management; signaling, multipurpose I/O | Load management; signaling, multipurpose I/O | Load management; signaling, multipurpose I/O |
updating…
Solar Energy
updating…
updating…
Additional information
Manufacturer | Fronius |
---|