Inverter ABB 10-12KW Energy

Description

HIGHLIGHTS

Updating..

Input (DC)PVI-10.0-I-OUTD-400PVI-12.0-I-OUTD-400
Absolute maximum DC input voltage (Vmax,abs)520 V520 V
Start-up DC input voltage (Vstart)200 V (adj. 120…350 V)200 V (adj. 120…350 V)
Operating DC input voltage range (Vdcmin…Vdcmax)0.7 x Vstart…520 V0.7 x Vstart…520 V
Rated DC input voltage (Vdcr)345 V345 V
Rated DC input power (Pdcr)10500 W12300 W
Number of independent MPPT2(5)2(5)
Maximum DC input power for each MPPT (PMPPTmax)6800 W6800 W
DC input voltage range with parallel configuration of MPPT at Pac220…470 V250…470 V
DC power limitation with parallel configuration of MPPTLinear derating from max to null [470V≤VMPPT≤520V]Linear derating from max to null [470V≤VMPPT≤520V]
DC power limitation for each MPPT with independent configuration of MPPT at Pacr , max unbalance example6800 W [285V≤VMPPT≤470V]
the other channel: Pdcr-6800W
[155V≤VMPPT≤470V]
6800 W [275V≤VMPPT≤470V]
the other channel: Pdcr-6800W
[220V≤VMPPT≤470V]
Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax)48.0 A / 24.0 A50.0 A / 25.0 A
Maximum input short circuit current for each MPPT29.0 A29.0 A
Number of DC inputs pairs for each MPPT22
DC connection typeTool Free PV connector WM / MC4Tool Free PV connector WM / MC4
Input protection
Reverse polarity protectionYes, from limited current sourceYes, from limited current source
Input over voltage protection for each MPPT – varistor22
Photovoltaic array isolation controlAccording to local standardAccording to local standard
DC switch rating for each MPPT (version with DC switch)32 A / 600 V32 A / 600 V
Output side
AC grid connection typeThree phase 3W or 4W+PEThree phase 3W or 4W+PE
Rated AC power (Pacr @cosφ=1 )10000 W12000 W
Maximum AC output power (Pacmax @cosφ=1)11000 W (312500 W
Maximum apparent power (Smax)11100 VA13300 VA
Rated AC grid voltage (Vac,r)400 V400 V
AC voltage range320…480 V320…480 V
Maximum AC output current (Iac,max)16.0 A18.0 A
Contributory fault current25.0 A25.0 A
Rated output frequency (fr)50 Hz / 60 Hz50 Hz / 60 Hz
Output frequency range (fmin…fmax)47…53 Hz / 57…63 Hz(2)47…53 Hz / 57…63 Hz(2)
Nominal power factor and adjustable range> 0.995, adj. ± 0.9 with Pacr =12.0 kW> 0.995, adj. ± 0.9 with Pacr =12.0 kW
Total current harmonic distortion< 2%< 2%
AC connection typeScrew terminal block, cable gland M40Screw terminal block, cable gland M40
Output protection
Anti-islanding protectionAccording to local standardAccording to local standard
Maximum AC overcurrent protection20.0 A20.0 A
Output overvoltage protection – varistor3 plus gas arrester3 plus gas arrester
Operating performance
Maximum efficiency (ηmax)97.30%97.30%
Maximum efficiency (ηmax)97.0% / –97.0% / –
Feed in power threshold30 W30 W
Stand-by consumption< 8 W< 8 W
Communication
Wired local monitoringPVI-USB-RS232_485 (opt.)PVI-USB-RS232_485 (opt.)
Remote monitoringVSN300 Wifi Logger Card(6) (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)VSN300 Wifi Logger Card(6) (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
Wireless local monitoringVSN300 Wifi Logger Card(6) (opt.VSN300 Wifi Logger Card(6) (opt.)
User interface16 characters x 2 lines LCD display16 characters x 2 lines LCD display
Environmental
Ambient temperature range-25…+60°C /-13…140°F
with derating above 50°C/122°F
-25…+60°C /-13…140°F
with derating above 45°C/113°F
Relative humidity0…100% condensing0…100% condensing
Noise emission< 50 dB(A) @ 1 m< 50 dB(A) @ 1 m
Maximum operating altitude without derating2000 m / 6560 ft2000 m / 6560 ft
Physical
Environmental protection ratingIP 65IP 65
CoolingNaturalNatural
Dimension (H x W x D)716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”
Weight< 45.8 kg / 99.0 lb< 45.8 kg / 99.0 lb
Mounting systemWall bracketWall bracket
Safety
Isolation levelHF transformerHF transformer
MarkingCE (50 Hz only)CE (50 Hz only)
Safety and EMC standardEN 50178, EN62109-1, EN62109-2,
AS/NZS3100, AS/NZS 60950, EN61000-3-2,
EN61000-3-3, EN61000-6-2, EN61000-6-3
EN 50178, EN62109-1, EN62109-2,
AS/NZS3100, AS/NZS 60950, EN61000-6-2,
EN61000-6-3, EN61000-3-11, EN61000-3-12
Grid standard (check your sales channel for availability)CEI 0-21, CEI 0-16, VDE 0126-1-1,
VDE-AR-N 4105, G83/2, G59/3, C10/11,
EN 50438 (not for all national appendices),
RD1699, RD 1565, AS 4777, ABNT NBR
16149, CLC/FprTS 50549
CEI 0-21, CEI 0-16, VDE 0126-1-1, VDE-AR-N
4105, G59/3, C10/11, EN 50438 (not for all
national appendices), RD1699, RD 1565, AS
4777, ABNT NBR 16149, CLC/FprTS 50549
Available products variants
StandardPVI-10.0-I-OUTD-400PVI-12.0-I-OUTD-400
With DC switchPVI-10.0-I-OUTD-S-400PVI-12.0-I-OUTD-S-400

updating…

Solar Energy

updating…

Additional information

Manufacturer

ABB

Origin

Italy