| Type designation | SG50CX |
| Input (DC) | |
| Max. PV input voltage | 1100 V |
| Min. PV input voltage / Start-up input voltage | 200 V / 250 V |
| Nominal PV input voltage | 585 V |
| MPP voltage range | 200 – 1000 V |
| MPP voltage range for nominal power | 550 – 850V |
| No. of independent MPP inputs | 5 |
| Max. number of PV strings per MPPT | 2 |
| Max. PV input current | 130 A |
| Max. current for input connector | 30 A |
| Max. DC short-circuit current | 200 A |
| Output (AC) | |
| AC output power | 55 kVA @ 40 ℃ / 50 kVA @ 45 ℃ |
| Max. AC output current | 83.6A |
| Nominal AC voltage | 3 / N / PE, 230 / 400 V |
| AC voltage range | 312 – 528 V |
| Nominal grid frequency / Grid frequency range | 50 Hz / 45 – 55 Hz, 60 Hz / 55 – 65 Hz |
| THD | < 3 % (at nominal power) |
| DC current injection | < 0.5 % In |
| Power factor at nominal power / Adjustable power factor | > 0.99 / 0.8 leading – 0.8 lagging |
| Feed-in phases / connection phases | 3/3 |
| Efficiency | |
| Max. efficiency / European efficiency | 98.7% / 98.4% |
| Protection | |
| DC reverse connection protection | Yes |
| AC short circuit protection | Yes |
| Leakage current protection | Yes |
| Grid monitoring | Yes |
| DC switch | Yes |
| AC switch | No |
| PV String current monitoring | Yes |
| Q at night | Yes |
| PID recovery function | optional |
| Overvoltage protection | DC Type II / AC Type II |
| General Data | |
| Dimensions (W*H*D) | 782*645*310mm |
| Weight | 62 kg |
| Isolation method | Transformerless |
| Degree of protection | IP66 |
| Night power consumption | ≤2 W |
| Operating ambient temperature range | -30 to 60 ℃ (> 45 ℃ derating) |
| Allowable relative humidity range (non-condensing) | 0 – 100 % |
| Cooling method | Smart forced air cooling |
| Max. operating altitude | 4000 m (> 3000 m derating) |
| Display | LED, Bluetooth+APP |
| Communication | RS485 / Optional: Wi-Fi, Ethernet |
| DC connection type | MC4 (Max. 6 mm²) |
| AC connection type | OT or DT terminal (Max.70 mm²) |
| Compliance | IEC 62109, IEC 61727, IEC 62116, IEC 60068, IEC 61683, VDE-AR-N 4105:2018, VDE-AR-N 4110:2018, IEC 61000-6-3, EN 50438, AS/NZS 4777.2:2015, CEI 0-21, VDE 0126-1-1/A1 VFR 2014, UTE C15-712-1:2013, DEWA |
| Grid Support | Q at night function, LVRT, HVRT,active & reactive power control and power ramp rate control |