Inverter 20-27.6KW Energy ABB

Description

HIGHLIGHTS

Updating..

Input (DC)TRIO-20.0-TL-OUTDTRIO-27.6-TL-OUTD
Absolute maximum DC input voltage (Vmax,abs)1000 V1000 V
Start-up DC input voltage (Vstart)430 V (adj. 250…500 V)430 V (adj. 250…500 V)
Operating DC input voltage range (Vdcmin…Vdcmax)0.7 x Vstart…950 V0.7 x Vstart…950 V
Rated DC input voltage (Vdcr)620 V620 V
Rated DC input power (Pdcr)20750 W28600 W
Number of independent MPPT22
Maximum DC input power for each MPPT (PMPPTmax)12000 W16000 W
DC input voltage range with parallel configuration of MPPT at Pac440…800 V500…800 V
DC power limitation with parallel configuration of MPPTLinear derating from max to null [800V≤VMPPT≤950V]Linear derating from max to null [800V≤VMPPT≤950V]
DC power limitation for each MPPT with independent configuration of MPPT at Pacr , max unbalance example12000 W [480V≤VMPPT≤800V]
the other channel: Pdcr-12000W
[350V≤VMPPT≤800V]
16000 W [500V≤VMPPT≤800V]
the other channel: Pdcr-16000W
[400V≤VMPPT≤800V]
Maximum DC input current (Idcmax) / for each MPPT (IMPPTmax)50.0 A / 25.0 A64.0 A / 32.0 A
Maximum input short circuit current for each MPPT30.0 A40.0 A
Number of DC inputs pairs for each MPPT1 ( 4 in -S2X and -S2F Versions)1 (5 in -S2X and -S2F Versions)
DC connection typeTool Free PV connector WM / MC4 (Screw terminal block on standard and -S2 versions)Tool Free PV connector WM / MC4 (Screw terminal block on standard and -S2 versions)
Input protection
Reverse polarity protectionInverter protection only, from limited current source, for standard and -S2 versions, and for
fused versions when max 2 strings are connected
Inverter protection only, from limited current source, for standard and -S2 versions, and for
fused versions when max 2 strings are connected
Input over voltage protection for each MPPT – varistor22
Input over voltage protection for each MPPT – plug in
modular surge arrester (-S2X version)
3 (Class II)3 (Class II)
Photovoltaic array isolation controlAccording to local standardAccording to local standard
DC switch rating for each MPPT (version with DC switch)40 A / 1000 V40 A / 1000 V
Fuse rating (versions with fuses )15 A / 1000 V15 A / 1000 V
Output side
AC grid connection typeThree phase 3W or 4W+PEThree phase 3W or 4W+PE
Rated AC power (Pacr @cosφ=1 )20000 W27600 W
Maximum AC output power (Pacmax @cosφ=1)22000 W30000 W
Maximum apparent power (Smax)22200 VA30000 VA
Rated AC grid voltage (Vac,r)400 V400 V
AC voltage range320…480 V320…480 V
Maximum AC output current (Iac,max)33.0 A45.0 A
Contributory fault current35.0 A46.0 A
Rated output frequency (fr)50 Hz / 60 Hz50 Hz / 60 Hz
Output frequency range (fmin…fmax)47…53 Hz / 57…63 Hz47…53 Hz / 57…63 Hz
Nominal power factor and adjustable range> 0.995, adj. ± 0.9 with P with max 22.2 kVA acr =20.0 kW, ± 0.8> 0.995, adj. ± 0.9 with P ± 0.8 with max 30 kVA acr =27.6 kW,
Total current harmonic distortion< 3%< 3%
AC connection typeScrew terminal block, cable gland PG36Screw terminal block, cable gland PG36
Output protection
Anti-islanding protectionAccording to local standardAccording to local standard
Maximum AC overcurrent protection34.0 A46.0 A
Output overvoltage protection – varistor44
Output overvoltage protection – plug in modular surge
arrester (-S2X version)
4 (Class II)4 (Class II)
Operating performance
Maximum efficiency (ηmax)98.20%97.30%
Maximum efficiency (ηmax)98.0% / 98.0%98.0% / 98.0%
Feed in power threshold40 W40 W
Stand-by consumption< 8W< 8W
Communication
Wired local monitoringPVI-USB-RS232_485 (opt.)PVI-USB-RS232_485 (opt.)
Remote monitoringVSN300 Wifi Logger Card(5) (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)VSN300 Wifi Logger Card(5) (opt.), PVI-AEC-EVO (opt.), VSN700 Data Logger (opt.)
Wireless local monitoringVSN300 Wifi Logger Card(5) (opt.)VSN300 Wifi Logger Card(5) (opt.)
User interfaceGraphic displayGraphic display
Environmental
Ambient temperature range-25…+60°C /-13…140°F with derating above 45°C/113°F-25…+60°C /-13…140°F with derating above 45°C/113°F
Relative humidity0…100% condensing0…100% condensing
Noise emission< 50 dB(A) @ 1 m< 50 dB(A) @ 1 m
Maximum operating altitude without derating2000 m / 6560 ft2000 m / 6560 ft
Physical
Environmental protection ratingIP 65IP 65
CoolingNaturalNatural
Dimension (H x W x D)1061 mm x 702 mm x 292 mm/ 41.7” x 27.6” x 11.5”716mm x 645mm x 222mm / 28.2” x 25.4” x 8.7”
Weight< 70.0 kg / 154.3 lb (Standard version)< 75.0 kg / 165.4 lb (Standard version
Mounting systemWall bracketWall bracket
Safety
Isolation levelTransformerlessTransformerless
MarkingCE (50 Hz only)CE (50 Hz only)
Safety and EMC standardEN 50178, EN62109-1, EN62109-2, AS/NZS3100, AS/NZS 60950, EN61000-6-2,
EN61000-6-3, EN61000-3-11, EN61000-3-12
EN 50178, EN62109-1, EN62109-2, AS/NZS3100, AS/NZS 60950, EN61000-6-2,
EN61000-6-3, EN61000-3-11, EN61000-3-12
Grid standard (check your sales channel for availability)CEI 0-21, CEI 0-16, VDE 0126-1-1, VDE-AR-N 4105, G59/3, C10/11,
EN 50438 (not for all national appendices), RD1699, RD 1565, AS 4777, BDEW,
ABNT NBR 16149, NRS-097-2-1, CLC/FprTS 50549, PEA, MEA
CEI 0-21, CEI 0-16, VDE 0126-1-1, VDE-AR-N 4105, G59/3, C10/11,
EN 50438 (not for all national appendices), RD1699, RD 1565, AS 4777, BDEW,
ABNT NBR 16149, NRS-097-2-1, CLC/FprTS 50549, PEA, MEA
Available products variants
StandardTRIO-20.0-TL-OUTD-400TRIO-27.6-TL-OUTD-400
With DC switchTRIO-20.0-TL-OUTD-S2-400TRIO-27.6-TL-OUTD-S2-400
With DC+AC switch and fuseTRIO-20.0-TL-OUTD-S2F-400TRIO-27.6-TL-OUTD-S2F-400
With DC+AC switch, fuse and surge arresterTRIO-20.0-TL-OUTD-S2X-400TRIO-27.6-TL-OUTD-S2X-400

updating…

Solar Energy

updating…

Additional information

Manufacturer

ABB

Origin

Italy

You've just added this product to the cart: