Spectro UV11
Type: UV-VIS
Auto setting wavelength.
Using your standard sample solutions, you can get a standard curve on the large LCD screen.
Include basic software, 10mm 4 cell Holder 4xGlass 10mm cuvette.
Function: Absorbance, Transmittance or Concentration measurements
+ Spectral Bandwitch 4nm Wavelength Accuracy ±2nm
+ Wavelength Repeatability 1nm
+ Output USB Port&Parallel Port printer
WAVELENGTH RANGE (NM)-200-1000
- Description
- Additional information
Description
HIGHLIGHTS
High quality silicon photometric diode detector and 1200 lines/mm grating ensure high accuracy and precision.
+ Optical System: Single Beam
+ Detector: Silicone Photo diode
System can also save the test results. Total 200 groups of data and 100 standard curves can be saved; it is convenient for check and reload.
You can achieve the following functions: I. Quantitative; II. Kinetics; III. Wavelength Scan; IV. Multi Wavelength; V. DNA/Protein.
Can display total 50 groups of data, 3 groups per screen. Can display standard curve and the curve equation.
Data can be restored after a sudden power cut.
Wavelength range | 200-1000nm |
Spectral Bandwitch | 4nm |
optical system | Single Beam , Grating 1200 lines/mm |
Wavelength Accuracy | ±2nm |
Wavelength Repeatability | 1nm |
Photometric Accuracy | ≤ ±0.5%T or ±0.003A@1A |
Photometric Range | 0-200%T , -0.3 -3A, 0-1999Conc. |
Stray Light | 0.3%T |
Stability | ±0.002A/h @500nm |
Detector | Silicon Photodiode |
Standard Cell Holder | 4-position 10mm cell changer |
Sample Compartment | Standard 10mm pathlength cuvette |
Light Source | Tungsten & Deuterium lamp |
Output | USB Port & Parallel Port (printer) |
Dimensions (WxDxH) | 470x370x180mm |
Weight | 14kg |
Large LCD screen (128×64 Dots)
Auto setting wavelength.
Tungsten lamp & Deuterium lamp can be tuned on/off individually to extend lifetime.
Pre-aligned design makes it convenient to change lamps.
Large sample compartment, it can accommodate 5-100mm path length cuvettes with optional holders. A variety of optional accessories are available.
The optional application software M.Wave Professional provides complete control of the spectrophotometer through the Built-in USB port.
Power Requirements | AC 110/220V 50/60Hz |
Spectrophotometer is the ideal instrument for education and QC laboratories.
They are widely used in colleges and enterprises for general quantitative analysis and experiments.
4-Cell Holder for 10mm Squ. Cuvette
4-Cell Holder for up to 50mm Squ. Cuvette
Reflectance Measurement Attachment (50 incident angle)
Cylindrical Cell Holder
Water-Jacketed Single Cell Holder
Micro Cell Holder
Test Tube Holder
8-Position Auto Cell Changer
Solid Sample Holder (Single Cell)
10mm Water-Jacket 4-Cell Holder
Thermal Printer
Stylus Printer
1. Peltier Unit 2. Sipper Unit Thermal Printer Stylus Printer 3. Peltier/Sipper System
SQUARE CURETTE | |
Square Curette Glass | 10mm/4pcs 20mm/4pcs 30mm/4pcs 50mm/4pcs 100mm/4pcs |
Square Curette Quartz | 10mm/2pcs 20mm/2pcs 30mm/2pcs 50mm/2pcs 100mm/2pcs |
MICRO CELL | |
Micro Cell | 100UL/1pcs |
Square Cuvettes Glass | 20mm/1pcs 30mm/1pcs |
FLOW CELL | |
SEIF Masking Cont. Flowthrough G.Cell | 5mm/1pcs 10mm/1pcs 20mm/1pcs 30mm/1pcs |
SEIF Masking Cont. Flowthrough Q.Cell | 5mm/1pcs 10mm/1pcs 20mm/1pcs 30mm/1pcs |
M. Wave Basic
The main functions of M.Wave Basic:
1) Quantitative Analysis
Coefficient Method
Set up a curve by standard samples
2) Kinetics
You can choose the Time Intervals(0.51.0, 2.0, 5.0, 10.0, 30.0 or 60.0 Seconds).
You can choose different Photometric Mode to display the curve.
(Transmittance-Time & Absorbance-Time)
3) Photometry Measurement
The test result can be displayed in Transmittance Mode and Absorbance Mode.
Additional information
Manufacturer | MRC |
---|---|
Origin | Israel |
Type | Manual |