Spectro V11D
Type: UV-VIS
Manually setting wavelength
Include basic software, 10mm 4 cell Holder 4x Glass 10mm cuvette.
Wavelength range: 200-1000nm
Spectral Bandwitch 4nm, Accuracy: ±2nm Repeatability 1nm
Function: Transmittance, Absorbance & Concentration modes
- Description
- Additional information
Description
HIGHLIGHTS
UV11D is the only model of manually setting wavelength in MRC families, but precise design and high quality components ensures excellent performance.
High quality silicon photometric diode detector and 1200 lines/mm grating ensure high accuracy and precision.
+ Optical System: Single Beam
+ Detector: Silicone Photo diode
Wavelength range | 200-1000nm |
Spectral Bandwitch | 4nm |
optical system | Single Beam , Grating 1200 lines/mm |
Wavelength Accuracy | ±2nm |
Wavelength Repeatability | 1nm |
Wavelength Setting | Manual |
Photometric Accuracy | ≤ ±0.5%T or ±0.003A@1A |
Photometric Range | 0-200%T , -0.3 -3A, 0-1999Conc. |
Stray Light | 0.3%T |
Stability | ±0.004A/h @500nm |
Display | 128*64 Dots LCD |
Photometric Mode | T, A, C, F |
Detector | Silicon Photodiode |
Standard Cell Holder | 4-position 10mm cell changer |
Sample Compartment | Standard 10mm pathlength cuvette |
Light Source | Tungsten & Deuterium lamp |
Output | USB Port & Parallel Port (printer) |
Dimensions (WxDxH) | 480x360x160mm |
Weight | 12kg |
Large LCD Screen (128×64 Dots).
Wavelength can be read out from the screen directly
Auto Zero and Blank.
Parallel port, printed directly.
Large sample compartment, it can accommodate 5-100mm path length cuvettes with optional holders.
Pre-aligned design ensures the user can change lamp conveniently.
Optional software PC software M.Wave Professional can expand the applications to Standard Curve Kinetics & wave length scan.
High quality silicon photometric diode detector and 1200 lines/mm grating ensure high accuracy and precision.
Power Requirements | AC 110/220V 50/60Hz |
It is widely used in high schools & colleges for general analysis & experiments.
4-Cell Holder for 10mm Squ. Cuvette
4-Cell Holder for up to 50mm Squ. Cuvette
Reflectance Measurement Attachment (50 incident angle)
Cylindrical Cell Holder
Water-Jacketed Single Cell Holder
Micro Cell Holder
Test Tube Holder
8-Position Auto Cell Changer
Solid Sample Holder (Single Cell)
10mm Water-Jacket 4-Cell Holder
Thermal Printer
Stylus Printer
1. Peltier Unit 2. Sipper Unit Thermal Printer Stylus Printer 3. Peltier/Sipper System
SQUARE CURETTE | |
Square Curette Glass | 10mm/4pcs 20mm/4pcs 30mm/4pcs 50mm/4pcs 100mm/4pcs |
Square Curette Quartz | 10mm/2pcs 20mm/2pcs 30mm/2pcs 50mm/2pcs 100mm/2pcs |
MICRO CELL | |
Micro Cell | 100UL/1pcs |
Square Cuvettes Glass | 20mm/1pcs 30mm/1pcs |
FLOW CELL | |
SEIF Masking Cont. Flowthrough G.Cell | 5mm/1pcs 10mm/1pcs 20mm/1pcs 30mm/1pcs |
SEIF Masking Cont. Flowthrough Q.Cell | 5mm/1pcs 10mm/1pcs 20mm/1pcs 30mm/1pcs |
M. Wave Basic
The main functions of M.Wave Basic:
1) Quantitative Analysis
Coefficient Method
Set up a curve by standard samples
2) Kinetics
You can choose the Time Intervals(0.51.0, 2.0, 5.0, 10.0, 30.0 or 60.0 Seconds).
You can choose different Photometric Mode to display the curve.
(Transmittance-Time & Absorbance-Time)
3) Photometry Measurement
The test result can be displayed in Transmittance Mode and Absorbance Mode.
Additional information
Manufacturer | MRC |
---|---|
Origin | Israel |
Type | Manual |