TYPE | Sunny Boy 3.0 | Sunny Boy 3.6 |
Input (DC) | ||
Max. generator power | 5500 Wp | 5500 Wp |
Max. input voltage | 600 V | 600 V |
MPP voltage range | 110 V to 500 V | 130 V to 500 V |
Rated input voltage | 365 V | 365 V |
Min. input voltage / initial input voltage | 100 V / 125 V | 100 V / 125 V |
Max. input current input A / input B | 15 A / 15 A | 15 A / 15 A |
Max. DC short-circuit current input A / input B | 20 A / 20 A | 20 A / 20 A |
Number of independent MPP inputs / strings per MPP input | 2 / A:2; B:2 | 2 / A:2; B:2 |
Output (AC) | ||
Rated power (at 230 V, 50 Hz) | 3000 W | 3680 W |
Max. apparent power AC | 3000 VA | 3680 VA |
Nominal AC voltage / range | 220 V, 230 V, 240 V / 180 V to 280 V | 220 V, 230 V, 240 V / 180 V to 280 V |
AC power frequency / range | 50 Hz, 60 Hz / -5 Hz to +5 Hz | 50 Hz, 60 Hz / -5 Hz to +5 Hz |
Rated power frequency / rated grid voltage | 50 Hz / 230 V | 50 Hz / 230 V |
Max. output current | 16 A | 16 A |
Power factor at rated power | 1 | 1 |
Adjustable displacement power factor | 0.8 overexcited to 0.8 underexcited | 0.8 overexcited to 0.8 underexcited |
Feed-in phases / connection phases | 1 / 1 | 1 / 1 |
Efficiency | ||
Max. efficiency / European Efficiency | 97.0% / 96.4% | 97.0% / 96.5% |
Protective devices | ||
Input-side disconnection point | ● | ● |
Ground fault monitoring / grid monitoring | ● / ● | ● / ● |
DC reverse polarity protection / AC short circuit current capability/ galvanically isolated | ● / ● / — | ● / ● / — |
All-pole-sensitive residual-current monitoring unit | ● | ● |
Protection class (as per IEC 61140) / overvoltage category (according to IEC 60664-1) | I / III | I / III |
General data | ||
Dimensions (W / H / D) | 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) | 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) |
Weight | 17.5 kg (38.5 lb) | 17.5 kg (38.5 lb) |
Operating temperature range | ‒25°C to +60°C (‒13°F to +140°F) | ‒25°C to +60°C (‒13°F to +140°F) |
Noise emission, typical | 25 dB(A) | 25 dB(A) |
Self-consumption (at night) | 5.0 W | 5.0 W |
Topology | Transformerless | Transformerless |
Cooling method | Convection | Convection |
Degree of protection (as per IEC 60529) | IP65 | IP65 |
Climatic category (as per IEC 60721-3-4) | 4K4H | 4K4H |
Max. permissible value for relative humidity (non condensing) | 100% | 100% |
Equipment | ||
DC connection / AC connection | SUNCLIX / AC connector | SUNCLIX / AC connector |
Display via smartphone, tablet, laptop | ● | ● |
Interfaces: WLAN / Ethernet / RS485 | ● / ● / ● | ● / ● / ● |
Communication protocols | Modbus (SMA, Sunspec), Webconnect, SMA Data | Modbus (SMA, Sunspec), Webconnect, SMA Data |
Shade management: integrated SMA ShadeFix | ● | ● |
Warranty: 5 / 10 / 15 years | ● / ○ / ○ | ● / ○ / ○ |
Certificates and approvals (more available upon request) | AS 4777.2, C10/11, CE, CEI 0-21, Dansk Energi DK1/2, DEWA, DIN EN 62109 / IEC 62109, EN 50438, EN 50549-1, G98/1, G99/1, IEC 61727, IEC 62116, IE-EN50438, NBR16149, NEN-EN50438, NRS 097-2-1, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR Erzeuger Typ A, PPC, PPDS, RD1699, RfG compliant, SI4777, UTE C15-712, VDE0126-1-1, VDE-AR-N 4105, VFR 2014 | AS 4777.2, C10/11, CE, CEI 0-21, Dansk Energi DK1/2, DEWA, DIN EN 62109 / IEC 62109, EN 50438, EN 50549-1, G98/1, G99/1, IEC 61727, IEC 62116, IE-EN50438, NBR16149, NEN-EN50438, NRS 097-2-1, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR Erzeuger Typ A, PPC, PPDS, RD1699, RfG compliant, SI4777, UTE C15-712, VDE0126-1-1, VDE-AR-N 4105, VFR 2014 |
Country availability of SMA Smart Connected | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK |
Standard features○ Optional features — Not available Data at nominal conditions Status: 03/2021 1) 4600 W / 4600 VA according to VDE-AR-N 4105 2) AS 4777: 21.7 A | ||
Type designation | SB3.0-1AV-41 | SB3.6-1AV-41 |
TYPE | Sunny Boy 4.0 | Sunny Boy 5.0 | Sunny Boy 6.0 |
Input (DC) | |||
Max. generator power | 7500 Wp | 7500 Wp | 9000 Wp |
Max. input voltage | 600 V | 600 V | 600 V |
MPP voltage range | 140 V to 500 V | 175 V to 500 V | 210 V to 500 V |
Rated input voltage | 365 V | 365 V | 365 V |
Min. input voltage / initial input voltage | 100 V / 125 V | 100 V / 125 V | 100 V / 125 V |
Max. input current input A / input B | 15 A / 15 A | 15 A / 15 A | 15 A / 15 A |
Max. DC short-circuit current input A / input B | 20 A / 20 A | 20 A / 20 A | 20 A / 20 A |
Number of independent MPP inputs / strings per MPP input | 2 / A:2; B:2 | 2 / A:2; B:2 | 2 / A:2; B:2 |
Output (AC) | |||
Rated power (at 230 V, 50 Hz) | 4000 W | 5000 W1) | 6000 |
Max. apparent power AC | 4000 VA | 5000 VA1) | |
Nominal AC voltage / range | 220 V, 230 V, 240 V / 180 V to 280 V | 220 V, 230 V, 240 V / 180 V to 280 V | 220 V, 230 V, 240 V / 180 V to 280 V |
AC power frequency / range | 50 Hz, 60 Hz / -5 Hz to +5 Hz | 50 Hz, 60 Hz / -5 Hz to +5 Hz | 50 Hz, 60 Hz / -5 Hz to +5 Hz |
Rated power frequency / rated grid voltage | 50 Hz / 230 V | 50 Hz / 230 V | 50 Hz / 230 V |
Max. output current | 22 A2) | 22 A2) | 26.1 A |
Power factor at rated power | 1 | 1 | 1 |
Adjustable displacement power factor | 0.8 overexcited to 0.8 underexcited | 0.8 overexcited to 0.8 underexcited | 0.8 overexcited to 0.8 underexcited |
Feed-in phases / connection phases | 1 / 1 | 1 / 1 | 1 / 1 |
Efficiency | |||
Max. efficiency / European Efficiency | 97.0% / 96.5% | 97.0% / 96.5% | 97.0 % / 96.6 % |
Protective devices | |||
Input-side disconnection point | ● | ● | ● |
Ground fault monitoring / grid monitoring | ● / ● | ● / ● | ● / ● |
DC reverse polarity protection / AC short circuit current capability/ galvanically isolated | ● / ● / — | ● / ● / — | ● / ● / — |
All-pole-sensitive residual-current monitoring unit | ● | ● | ● |
Protection class (as per IEC 61140) / overvoltage category (according to IEC 60664-1) | I / III | I / III | I / III |
General data | |||
Dimensions (W / H / D) | 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) | 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) | 435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) |
Weight | 17.5 kg (38.5 lb) | 17.5 kg (38.5 lb) | 17.5 kg (38.5 lb) |
Operating temperature range | ‒25°C to +60°C (‒13°F to +140°F) | ‒25°C to +60°C (‒13°F to +140°F) | ‒25°C to +60°C (‒13°F to +140°F) |
Noise emission, typical | 25 dB(A) | 25 dB(A) | 25 dB(A) |
Self-consumption (at night) | 5.0 W | 5.0 W | 5.0 W |
Topology | Transformerless | Transformerless | Transformerless |
Cooling method | Convection | Convection | Convection |
Degree of protection (as per IEC 60529) | IP65 | IP65 | IP65 |
Climatic category (as per IEC 60721-3-4) | 4K4H | 4K4H | 4K4H |
Max. permissible value for relative humidity (non condensing) | 100% | 100% | 100% |
Equipment | |||
DC connection / AC connection | SUNCLIX / AC connector | SUNCLIX / AC connector | SUNCLIX / AC connector |
Display via smartphone, tablet, laptop | ● | ● | ● |
Interfaces: WLAN / Ethernet / RS485 | ● / ● / ● | ● / ● / ● | ● / ● / ● |
Communication protocols | Modbus (SMA, Sunspec), Webconnect, SMA Data | Modbus (SMA, Sunspec), Webconnect, SMA Data | Modbus (SMA, Sunspec), Webconnect, SMA Data |
Shade management: integrated SMA ShadeFix | ● | ● | ● |
Warranty: 5 / 10 / 15 years | ● / ○ / ○ | ● / ○ / ○ | ● / ○ / ○ |
Certificates and approvals (more available upon request) | AS 4777.2, C10/11, CE, CEI 0-21, Dansk Energi DK1/2, DEWA, DIN EN 62109 / IEC 62109, EN 50438, EN 50549-1, G98/1, G99/1, IEC 61727, IEC 62116, IE-EN50438, NBR16149, NEN-EN50438, NRS 097-2-1, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR Erzeuger Typ A, PPC, PPDS, RD1699, RfG compliant, SI4777, UTE C15-712, VDE0126-1-1, VDE-AR-N 4105, VFR 2014 | AS 4777.2, C10/11, CE, CEI 0-21, Dansk Energi DK1/2, DEWA, DIN EN 62109 / IEC 62109, EN 50438, EN 50549-1, G98/1, G99/1, IEC 61727, IEC 62116, IE-EN50438, NBR16149, NEN-EN50438, NRS 097-2-1, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR Erzeuger Typ A, PPC, PPDS, RD1699, RfG compliant, SI4777, UTE C15-712, VDE0126-1-1, VDE-AR-N 4105, VFR 2014 | AS 4777.2, C10/11, CE, CEI 0-21, Dansk Energi DK1/2, DEWA, DIN EN 62109 / IEC 62109, EN 50438, EN 50549-1, G98/1, G99/1, IEC 61727, IEC 62116, IE-EN50438, NBR16149, NEN-EN50438, NRS 097-2-1, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR Erzeuger Typ A, PPC, PPDS, RD1699, RfG compliant, SI4777, UTE C15-712, VDE0126-1-1, VDE-AR-N 4105, VFR 2014 |
Country availability of SMA Smart Connected | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK | AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK |
Standard features○ Optional features — Not available Data at nominal conditions Status: 03/2021 1) 4600 W / 4600 VA according to VDE-AR-N 4105 2) AS 4777: 21.7 A | |||
Type designation | SB4.0-1AV-41 | SB5.0-1AV-41 | SB6.0-1AV-41 |