Inverted Material Science Microscopes IM 500 BD

> Reflected light microscopy is the choice for imaging opaque samples. The sample is illuminated from above through the objective. Because light is unable to pass through opaque samples, it is directed on the surface and returned to the objective by reflection
> Inverted reflected light microscope has two eyepieces, normally 10x magnification, and, in most cases, a tube head dedicated for using a camera system, this connection can be on the viewing tube or on the microscope body.
> The nosepiece is capable of holding from four to six objectives, these can be recognized by the Epi tag on their external cover.
> Mechanical stage sample holder can be moved in the XY axis , while the entire stage can be moved up and down through coarse and fine focusing mechanism. In certain configurations these movements can be automated by using motorized stage systems.
> The illumination system is built-in with dedicate lamp housing, the generated light passes through a vertical illuminator to the nosepiece and then deflected to the viewing tube head.
> The sample is placed upside down on the stage with the surface to be observed facing the objective.
> Several techniques are commonly used: Brightfield, Darkfield, Polarized light and Differential Interference Contrast (DIC) and fluorescence.

Description

HIGHLIGHTS

Microscopes is designed to supply state-of-the-art reliability and cost/efficient high performance

The advantage of these microscope type is that samples can have bigger shape with only one flat surface

Software is leading-edge digital imaging software for a wide variety of metallurgical applications, for labs set up, for quality control or quality assurance, production, inspection, failure analysis and research

echoLAB offers also necessary accessories, high performance cameras and different software from basic image capture (included with the camera) to advanced automated image analysis for particle sizing and metallurgical analysis (e.g. grain size, inclusion counts, porosity etc).

Optical systemCCIS
Total magnification50x – 100x – 200x – 500x
EyepieceWF 10x (ø22mm)
Plan achromatic objectives long working distancePL L 5x/0.12BD WD=9.70mm
PL L 10x/0.25BD WD=9.30mm
PL L 20x/0.40BD WD=7.23mm
PL L 50x/0.70BD WD=2.50mm
HeadTrinocular
Inclination of 45°
Interpupillary distance 53mm-75mm
Diopter adjustable ±5
NosepieceQuintuple back ball bearing inner locating
StageDouble layer mechanical with glass insert, overall size 242x220mm
Metal platen with inner hole ø21mm
Coaxial motion 30x30mm
Focusing SystemCoaxial coarse/fine focus system, minimum division of fine focusing 2μm
Tensional adjustable with upper stop
Reflected illuminationllumination with integrated field diaphragm and aperture diaphragm
12V 50W halogen lamp with brightness control
Polarization360° rotatable polarizer
Analyzer360° rotatable analyzer
FilterYellow for reflected light
Blue for reflected light
Green for reflected light
Frosted glass filter for reflected light
Contrast techniquesBrightfield: Yes
Darkfiled: Yes
DIC: Not available
POL Contrast: Yes
Power suply230V ±10% – 50/60Hz -1Ph – 30W
ComputerYes

> Reflected light microscopy is the choice for imaging opaque samples. The sample is illuminated from above through the objective. Because light is unable to pass through opaque samples, it is directed on the surface and returned to the objective by reflection.
> Most common samples are : metals, plastic materials, wood, silicon, ceramics etc

IM E-500-01 Eyepiece WF10x (ø22mm) crosshair 0.1mm/Div
IM O-500-21 Long working distance objective PL L 40x/0.60 WD=3.68mm
IM O-500-22 Long working distance objective PL L 60x/0.70 WD=3.18mm
IM O-500-23 Long working distance objective PL L 80x/0.80 WD=1.28mm
IM CA-500-91 Camera adapter 1x
IM CA-500-92 Camera adapter 0.5x with dividing 0.1mm/Div

Updating…

  1. echoImage Capture 2.0

User-friendly interface, complete camera parameter control,
advanced image processing functions, live and still image
measurements provided for highly efficient workflow
echoImage Capture 2.0 provides the full control of echoCAM:
> Exposure time
> Color control, red, green and blue channels
> Gain setting to adjust the image brightness
> White balance
> Saturation
> Advanced image processing functions integrated into echoImage Capture 2.0 including:
– fluorescence combination
– high dynamic range
– focus stacking
– image stitching

2. e-MET Pro

e-METPro metallographic software is leading-edge digital imaging software for a wide variety of metallurgical applications, for labs set up, for quality control or quality assurance, production, inspection, failure analysis and research.
e-METPro has many image analysis features including:
> ASTM Grain Size Analysis
> Plating, Coating & other Layer Thickness
> Particle Counts and Size Distribution
> Area Fractions
> Porosity
> ASTM Nodularity
> Ferrite/Pearlite
> ASTM Flake Size Classification
> Primary Dentrite Arm Spacing
> Secondary Dentrite Arm Spacing

Additional information

Manufacturer

Echolab

Origin

Italy

Type

Manual

You've just added this product to the cart: