CRYOSTATIC BATH
The bath is an instrument used to calibrate transducers, RTD and temperature- measuring sensors in the field and in the laboratory. The possibility to generate positive and negative temperature ramps makes it suitable for use in calibrating and testing thermostats.
- Description
- Additional information
Description
HIGHLIGHTS
The bath consists of a stainless tank with capacity of 10 litres
It is equipped with a new PID microprocessor controller with a resolution up to 0.01°C
Compliance with ISO 9000 regulations.
– Temperature range: | -40°C…+125°C |
– Stability: | ±0.05°C |
– Uniformity: | 0.02°C radial and axial |
– Stability indication: | audiovisual |
– Accuracy: | ±0.2°C at +120°C |
– Display resolution: | 0.01°C |
– Temperature indication: | °C / °F switchable |
– Interface: | RS232 |
– Thermostat test circuit: | 12V |
– Ramp function: | yes |
– Switch test: | |
– Bath containter: | Stainless steel, usable diamter 85 mm, depth 340 mm |
– Voltage: | 230 VAC ±10% (optional, on request: 115 VAC) |
– Power: | 2500w |
– Weight: | 60 kg (Shipping weight approx. 74 kg) |
– Dimension: | 450 x 450 x 925 / 1300 mm |
– Voltage: | 230 VAC ±10% (optional, on request: 115 VAC) |
– Power: | 2500 W |
Applications:
+ Control calibration of temperature sensors in laboratory, in conformity with ISO 9000 standards
+ Control of thermostats
+Automatic computer-controlled calibration
– Can with 10 kg ehylen Glycol |
to be used in temperature range -40°C…+80°C |
– Can with 9 kg silicone oil 47V20 |
to be used in temperature range -20°C…+125°C |
– Can with 9 kg silicone oil 47V100 |
to be used in temperature range +20°C…+200°C |
– PC-Software LR-Cal AQ2sp $259 |
incl. RS232-interface lead |
Temperature sensor calibration: |
Automatic calibration routine for all type of temperature sensors with advanced features such reference sensor stabilization, time-calibration data are automatically populated and stored for printing report. This procedure can also be ran in manual mode to allow the operator to manually enter the data. This is particular useful when calibrating temperature device such as digital thermometer or analogue thermometers. |
Stress test: |
Simply set MAX and MIN value and the software will run an automatic stress test on single sensor or a batch. |
Advance thermostat calibration: |
Simply set the open and close temperature limits, type of thermostat, typ of test and the software will automatically run the test. |
Updating
Additional information
Origin | Germany |
---|---|
Type | Manual |